Modius Data Center Blog

Data Center Optimization Roadmap

Posted by Marina Thiry on Thu, Jun 02, 2011 @ 01:29 PM

Speaking to a standing-room-only audience at the 2011 Uptime Symposium, Modius CEO Craig Compiano talked about the evolution of data center maturity: keeping pace with business needs. He introduced Modius’ Data Center Optimization Roadmap, which illustrates how optimization capabilities can be logically divided and accomplished in incremental steps. These steps deliver tangible benefits that continue to be leveraged as data center capabilities mature and become more relevant to the enterprise it supports.

Data Center, Optimization

The value of this roadmap immediately resonates with anyone who has worked on a long-term IT project—like managing a data center, for instance. All too often failures occur because the project team did not have the foresight to discern how their technology implementation might evolve over time. Consequently, early investments become outmoded in about 18 months, and the stakeholders are confronted with rapidly diminishing returns on their investment, if they are ever fully realized at all.

Instead of thinking about adding functionality and capacity in terms of incremental hardware (e.g., adding more servers), consider maximizing the capacity of your current investment, such that resources are more economically utilized within the existing infrastructure (e.g., identifying stranded capacity). Let’s take a closer look at the Data Center Optimization Roadmap to see how this can be accomplished.

describe the image

Click Image to Zoom

Modius sees the operational maturity of the data center in three stages. At each stage, the operational maturity of the data center increases with the level of strategic relevance it provides to the enterprise.

Stage 1 is device-centric: Continuous optimization requires gaining visibility of data center assets—from racks to CRACs—including those assets at different sites. Whether assets are being monitored from across the hall or across the continent, granular visibility into each device is necessary to understand how resources are being utilized by themselves and within the larger system that is the network.

The only way to accomplish this is by measuring where, when, and at what rate power is being consumed. Device-level visibility enables us to eke every kW of power, to maintain safe yet miserly cooling levels, and to ensure every square foot of the data center floor is effectively being used. (Walking around the data center floor and spot checking metered readings is no longer effective.)

With this device-level insight, you can identify tactical ways of maximizing utilization or reducing energy consumption. And, as a result of more efficient use of resources, businesses can defer capital expenses.

Stage 2 is business user-centric: The second stage in advancing data center optimization requires the alignment of data center performance information with the business user’s requirements. (By business users, we mean either internal users, such as a department or a cost center at an enterprise, or external users, such as the customers at a co-lo facility.) This level of optimization can only be achieved once the mechanisms are in place to ensure visibility of data center assets by their end users, per Stage 1. For example, monitoring and decision support tools must have the ability to logically sort and filter equipment by business groups, rather than the physical location of equipment in a data center (e.g., racks, rows or zones). Likewise, these tools must be flexible to accommodate business-driven time periods, rather than time periods convenient only to data center operations.

By enabling this business user-centric view—that is, by making data center operational intelligence meaningful to the end-users of the data center—IT and Facility personnel can now engage business users in a productive dialog about how their business requirements impact data center resources. Now, data center managers can begin to optimize throughput and productivity in a way that is meaningful to the business, which significantly advances the strategic relevance of the data center to the enterprise.

Stage 3 is enterprise-centric:  The third stage in advancing data center optimization requires making available data center operational intelligence with enterprise business intelligence (BI).  We are not suggesting anything complicated or unwieldy, only that by including data center performance and resource data, enterprises can provide a more complete picture of the true cost of doing business. By aligning “back end” data center operations with “front end” enterprise business processes, we can understand how market pressures impact the infrastructure, which in turn helps improve business continuity and mitigate risk.

For example, product and marketing managers can now have visibility into the data center resources supporting their web services. They can drill down to their back-office systems and  account for the commissioning and decommissioning servers, plus the energy and human capital required to run and manage those services. Another example: supply chain managers or sourcing managers can now see where and at what rate energy is being consumed across data center operations, enterprise-wide. This enables them to make better decisions about where to source energy, in addition to forecasting how much is needed.

These improvements are evidenced by enterprise agility—enterprises that can rapidly respond to a dynamic market and economic pressures. It is at this stage of maturity in data center operations that a data center can have a profound impact on whether a business can compete and win in the marketplace. 

describe the image Different isn't always better, but better is always different.
Marina Thiry, Director of Product Marketing

Topics: facility, Uptime Symposium, Craig Compiano, Data-Center-Best-Practices, Optimizing, DCIM, monitoring, Roadmap, optimization, infrastructure

The Water Cooler as a Critical Facility Infrastructure

Posted by Jay Hartley, PhD on Mon, May 02, 2011 @ 04:31 PM

Any data center manager can rattle off the standard list of critical facility equipment in the data center: generator, transfer switch, UPS, PDU, CRAC, fire system, etc. At times, however, one must take a step back and broaden one's view when determining what is critical. Unfortunately, too often we don't realize we're missing something important until after disaster strikes. In the hopes of heading off some future disasters, I share with you the following cautionary tale. I'll give you the take-away message in advance: "Look up!"

Scene:  A corporate office tower in Anytown, USA. A data center consumes the bulk of one floor. It is an efficient, well-maintained data center, with dual, dedicated utility feeds supplying a 2N-redundant power system, backup generator, and redundant chillers. It also boasts a years-long history of non-stop 100% reliable operation.

Blog   Water CoolerThe office floors above the data center all have essentially identical layouts, consisting of conference rooms, cube farms, and the occasional honest-to-goodness office.  Centrally located on each floor is an efficient, well-maintained kitchenette. In each kitchenette is a water cooler. Like many of its kind where the tap water is potable, this water cooler is plumbed directly to the sink. The ¼-inch white plastic tubing is anchored in place with small brass ferrules. This system has been doing yeoman's work for years, reliably delivering chilled, filtered drinking water to the employees with better than 99% up time, allowing for scheduled maintenance.

Action:  Disaster strikes, in accordance with Murphy's Law, late one weekend night. The water cooler’s plastic plumbing finally succumbs to age and stress. Water streams onto the floor unchecked, quickly covering the linoleum surface and finding its way into the wall. There it heads in water's favorite direction, down, passing easily through the matching kitchenette walls in the identical floor plans below.

The water continues until reaching a floor with a dramatically different layout. Temporarily stopped in its pursuit of gravity, the water gathers its forces, soaking into the obstruction until eventually, like the plastic tube, the ceiling tile succumbs. The next obstruction happens to be a PDU and a couple of neighboring server racks in the data center. They too succumb, we assume rather spectacularly.

Data Center Water LeakMeanwhile, back in the kitchenette, the leak is discovered during a security sweep and the flow is cut off, but human intervention has come too late for the electronics down below. Power redundancy saved all servers that were not directly water-damaged, so only a few internal business applications took an uptime hit, along with the kitchenette. Over $100,000 of damage, thanks to the failure of a few pennies of plastic tubing in a “non-critical” part of the facility.

 

Solution:  One could easily focus on the data center itself and protecting its equipment:  Place catch basins in the ceiling and extend the raised-floor leak detection system into them. That would help, and perhaps give a bit more warning. Not a bad idea in any case, if you have the time and money. Better solution? Inexpensive, off-the-shelf, floor leak detectors come in kits with automatic shut-off valves. Available online or in your local hardware store for home use in laundry rooms. An audible alarm is nice, but does an alarm make a noise if no one is there to hear it? Definitely get one with a second, normally-closed contact closure to link into your monitoring system. (You do have one, don’t you? Consider OpenData ME, SE, or EE!) Stop the leak early, and get advanced notice.

While you're at it, pick one up for that efficient, well-maintained, and oh-so-convenient second-floor laundry room in your home!

I hope you've enjoyed this tale. In the coming weeks, I'll share additional stories from the field as well as my musings on monitoring, instrumentation, and metrics. Visit my blog next week for insights on metering total energy for PUE—and a tip shared about the ATS.

Topics: Data-Center-Best-Practices, critical facility, leak detection, Dr-Jay, Data-Collection-and-Analysis, Sensors-Meters-and-Monitoring, Uptime-Assurance, monitoring

Getting the Most of Data Center Modularization: Optimizing in Near Real-Time

Posted by Marina Thiry on Sun, May 01, 2011 @ 05:31 PM

The challenge with data center capacity management lies not in what to do, but how to do it in a dynamic and complex environment. Traditional data centers typically were housed in one giant room with a single, integrated power and cooling system to service the entire room. This meant the energy expended to cool the room was fairly constant regardless of the actual IT load. Today’s modularized data center architecture is more energy efficient. It is designed to scale with the deployment volume of IT equipment. As IT equipment and computational workloads fluctuate with business demand, so too should the power and cooling of the data center.

Modularization helps the data center’s power and cooling systems run truly proportional to the computational demand and, thus, is less wasteful. By optimizing infrastructure performance, more servers can be supported in the data center with the same power and cooling. To fully appreciate its impact on capacity gains, first consider the how the principles of modularization can be applied throughout the entire facility:

Modular Design Data CenterPhysical Layout – Just as one manages power usage in a home by turning out the lights in unoccupied rooms, one can also manage data center power. By compartmentalizing the data center into energy zones or modules, with independent controls for power, cooling, and humidity, each module can be independently “lit up” as needed. Modularization can be achieved by erecting walls, hanging containment curtains, or by using pods, i.e., enclosed compartments of IT racks that employ a centralized environmental management system to provide cool air at intake and keep warm air at the exhaust.

IT Systems Architecture – IT infrastructure can be modularized, and should be done in conjunction with IT staff and end-user customers (business units) who own the applications deployed on servers. IT modularization involves grouping together servers, storage, and networking equipment that can be logically deployed in the same module. For example, when business computational demand is low, all corporate applications—such as the corporate intranet, internal email, external Web presence, e-commerce site, ERP applications, and more—can be deployed on the same module while the other modules in the data center remain “unlit” to save energy. As the business grows, more servers can be deployed and additional modules commissioned for IT use. For instance, all corporate intranet applications can be deployed in one module with external applications deployed in another module.

Modius AHU OptimizationPower and Cooling Infrastructure – Right-sizing the facilities infrastructure follows the modularization of the physical layout. As the modules—zones or pods—are created
for the physical layout, the power and cooling infrastructure are deployed in corresponding units that independently service each module. Separate UPSs, PDUs and power systems, along with CRAC units, condensers, or chillers, are sized appropriately for each module. This allows the scalable expansion of the facilities infrastructure as IT equipment expands.

The principles of modularization summarized above are proven optimization strategies that can extend the life of the data center. Optimizing in near real-time delivers a higher yield from existing resources. It enables us to get more utilization out of power, cooling and space.  

If your data center infrastructure management tools fall short enabling continuous optimization, then let us show you how OpenData can help in this 20-minute Modius OpenData webcast: http://info.modius.com/data-center-monitoring-webcast-demo-by-modius

Topics: Data-Center-Best-Practices, Capacity, Efficiency, monitoring, optimization, Modularization, Capacity-Management